 XIE Wenbing,ZHAO Xiangen,XIAO Pei,et al.Comparative Analysis on Lightning Surge Response of UHVAC Large-span River-crossing Transmission Line Based on FDTD and EMTP[J].High Voltage Apparatus,2019,55(09):187-193.[doi:10.13296/j.1001-1609.hva.2019.09.025]
点击复制

基于FDTD和EMTP的特高压大跨越线路雷击暂态 过程对比分析()
分享到:

《高压电器》[ISSN:1001-1609/CN:61-11271/TM]

卷:
第55卷
期数:
2019年09期
页码:
187-193
栏目:
研究与分析
出版日期:
2019-09-30

文章信息/Info

Title:
Comparative Analysis on Lightning Surge Response of UHVAC Large-span River- crossing Transmission Line Based on FDTD and EMTP
作者:
谢文炳1 赵贤根2 肖 佩2 傅智为1 吴文斌1 何俊佳2
(1. 国网福建省电力有限公司电力科学研究院, 福州 350000; 2. 华中科技大学强电磁工 程与新技术国家重点实验室, 武汉 430074)
Author(s):
XIE Wenbing1 ZHAO Xiangen2 XIAO Pei2 FU Zhiwei1 WU Wenbin1 HE Junjia2
(1. State Grid Fujian Electric Power Corporation Research Institute, Fuzhou 350000, China; 2. State Key Laboratory of Advanced Electromagnetic Engineering and Technology of Huazhong University of Science and Technology, Wuhan 430074, China)
关键词:
大跨越线路 特高压 雷电暂态特性 FDTD EMTP 感应分量 注入分量
Keywords:
large-span river-crossing transmission line UHVAC lightning surge response FDTD EMTPinduced voltage injected current
DOI:
10.13296/j.1001-1609.hva.2019.09.025
摘要:
大跨越线路的杆塔高、档距长,反击闪络风险高,准确分析其雷击暂态过程,对于保 证特高压线路的安全运行具有重要意义。文中针对淮南—上海特高压工程南通—苏州段的大跨 越输电线路,分别建立了该线路雷击暂态过程的FDTD和EMTP模型,得到了大跨越线路的杆塔横 担与塔顶电压、导线电压和绝缘子串过电压,并开展了对比分析,结果表明:采用Hara提出的 杆塔多波阻抗模型,EMTP计算得到的横担和塔顶电压远大于FDTD计算结果;若不考虑感应分量 ,EMTP计算得到的导线电压大于FDTD计算结果;上述结果导致EMTP计算得到的绝缘子串过电压 远高于FDTD计算结果。
Abstract:
For accurate analysis of lightning surge response of large-span river- crossing transmission line to ensure the safety of a power system,FDTD and EMTP models of the Nantong-Suzhou river-crossing transmission line in the Huainan- Shanghai UHVAC project are built. The voltages of the tower top, crossarms, phase conductors and insulator strings are calculated via both of the models, and comparative analysis is carried out. It is concluded that: 1)EMTP a chieves much higher voltages of the tower top and crossarms than FDTD if the multistory transmission tower model proposed by Hara is used for the EMTP model; 2)EMTP achieves much higher voltages of phase conductors than FDTD if the induced voltage from the current in lightning channel is ignored; and 3)EMTP achieves much higherover voltages of insulator strings than FDTD.

参考文献/References:

[1] 王东举,周 浩,陈稼苗,等. 特高杆塔的多波阻抗模型设计及雷击暂态特性分析[J]. 电网技术,2007,31(23): 11-16. WANG Dongju,ZHOU Hao,CHEN Jiamiao,et al. Design of multi-surge impendence model for ultra-high transmission tower and analysis on its transient characteristics caused by lightning stroke[J]. Power System Technology,2007,31(23): 11-16.
[2] 胡吉磊. 舟山与大陆联网大跨越370 m高塔防雷设计研究[D]. 华北电力大学, 2011. HU Jilei. The study on the lightning prevention design of 370 m tower used in the large crossing of Zhoushan[D]. North China Electric Power University,2011.
[3] 詹花茂. 输电线路特高杆塔雷电过电压的理论与试验研究[D]. 武汉:华中科技大 学,2002. ZHAN Huamao. Theoretical and experimental study on lightning voltage of ultra-high transmission tower[D]. Wuhan:Huazhong University of Science and Technology,2002.
[4] MOTOYAMA H,KINOSHITA Y,NONAKA K,et al. Experimental and analytical studies on lightning surge response of 500 kV transmission tower[J]. IEEE Transactions on Power Delivery,2009,24(4): 2232-2239.
[5] TAKAMI J,TSUBOI T,YAMAMOTO K,et al. Lightning surge response of a double-circuit transmission tower with incoming lines to a substation through FDTD simulation[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2014, 21(1): 96-104.
[6] TAKAMI J,TSUBOI T,YAMAMOTO K,et al. Lightning surge into a substation at a back-flashover and review of lightning protective level through the FDTD simulation[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2014, 21(3): 1044-1052.
[7] TRAN H T,BABA Y,NAGAOKA N,et al. FDTD simulation of lightning surges on overhead wires in the presence of corona discharge[J]. IEEE Transactions on Electromagnetic Compatibility,2012,54(6): 1234-1243.
[8] CHENGUO Y,HAO W,YAN M,et al. Finite difference time domain simulation of lightning transient electromagnetic fields on transmission lines[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2013,20(4): 1239-1246.
[9] 吴耀辉. 基于FDTD的雷击杆塔瞬态响应仿真研究[D]. 武汉:华中科技大学, 2012. WU Yaohui. Analytical studies on lightning surge response simulation of transmission tower by FDTD[D]. Wuhan:Huazhong University of Science and Technology,2012.
[10] NODA T,YOKOYAMA S. Thin wire representation in finite difference time domain surge simulation[J]. IEEE Transactions on Power Delivery,2002,17(3): 840 -847.
[11] LIAO Z,WONG H L,YANG B,et al. A transmitting boundary for transient wave analysis[J]. Science in China (Series A),1984,27(10): 1063-1076.
[12] BABA Y,RAKOV V A. Electromagnetic models of the lightning return stroke[J]. Journal of Geophysical Research,2007,112(D4): 1984-2012.
[13] RAKOV V A. Lightning return stroke speed: A review of experimental data[C]//27th International Conference on Lightning Protection (ICLP)[S.l.]: [s.n.],2004:1-7.
[14] GORIN B N,SHKILEV A V. Measurements of lightning currents at the Ostankino tower[J]. Elektrichestvo,1984(8): 64-65.
[15] HARA T,YAMAMOTO O. Modelling of a transmission tower for lightning- surge analysis[J]. IEE Proceedings-Generation,Transmission and Distribution,1996 ,143(3): 283-289.
[16] HARA T,YAMAMOTO O,HAYASHI M,et al. Empirical formulas of surge impedance for single and multiple vertical cylinder[J]. T. IEE Japan,1990(110): 129-137.
[17] MARTI J R. Accurate modelling of frequency-dependent transmission lines in electromagnetic transient simulations[J]. IEEE Transactions on Power Apparatus and Systems,1982(1): 147-157.
[18] 林福昌. 高电压工程[M]. 北京:中国电力出版社,2006. LIN Fuchang. High voltage engineering[M]. Beijing:China Electrical Power Press,2006.
[19] 刘 强,谷定燮,张元芳. 雷击杆塔塔顶时导线上感应电压敏感性分析[J]. 高电 压技术,2005,31(3): 31-33. LIU Qiang,GU Dingxie,ZHANG Yuanfang. Sensitivity analysis of lightning performance calculations for transmission lines[J]. High Voltage Engineering,2005,31(3): 31-33.
[20] 交流电气装置的过电压保护和绝缘配合:DL/T 620—1997[S]. 1997. Overvoltage protection and insulation coordination for ac electrical installations:DL/T 620— 1997[S]. 1997.
[21] GOLDE R H. Lightning[M]. Physics of lightning, London:Academic Press Inc., 1977: 377.
[22] BAHA Y,ISHII M. Numerical electromagnetic field analysis on lightning surge response of tower with shield wire[J]. IEEE Transactions on Power Delivery, 2000,15(3):1010-1015.

备注/Memo

备注/Memo:
收稿日期:2019-01-22; 修回日期:2019-03-25谢文炳(1988—),男,工程师,主要研究方向为输电线路运维技术。
更新日期/Last Update: 2019-09-10