摘要
本文采用模拟电荷法对压气式SF
6
断路器模型灭弧室静电场进行计算
通过分析100%开距和50%开距两种情况的计算结果
发现下游电极头部电场强度最大
而且喷口的存在对电场分布具有很大影响。
Abstract
The electric field of the interrupter of the puffer SF6breaker model was computed using a charge simulation method. Analyzing the results of 100% and 50% gap dis tances
th e maximum stress was found on the top of the downstream el ectrode. And the extistence of the nozzle affects the electric field distribution greatly.