LIU Guangyi, CAO Rui, LU Yang, et al. Diagnosis of Steady State Electron Density Distribution in Air Arc by Emission Spectroscopy[J]. High voltage apparatus, 2024, 60(3): 144-150.
LIU Guangyi, CAO Rui, LU Yang, et al. Diagnosis of Steady State Electron Density Distribution in Air Arc by Emission Spectroscopy[J]. High voltage apparatus, 2024, 60(3): 144-150. DOI: 10.13296/j.1001-1609.hva.2024.03.018.
and the study of its microscopic parameters in the steady state stage is of great significance for accurately grasping the reaction mechanism inside the plasma. Emission spectroscopy is a mature technique for diagnosing plasma electron density
which has such advantages as non-contact measurement
transient detection
high sensitivity
fast response
and simple instrumentation. In this paper
the
H
α
656.28 nm spectral line is used as the characteristic spectral line
and graphite is used as the electrode material to
measure the emission spectrum of the air arc under the conditions of 250 A and 200 V. Abelian inverse transformation and Viogt off-line fitting are performed on the emission spectrum obtained from the experiment
Stark broadening is obtained by deconvolution
and finally the radial distribution of the air arc electron number density is obtained. At the same time
the Thomson scattering method is used to measure the electron number density of the air arc under the same parameter conditions to verify the correctness of the emission spectrometry measurement results. It is verified that the measurement results of the two methods have good consistency. This experiment provides a reference idea and method for the measurement of air arc plasma electron number density.