KANG Ailiang, LIN Lingyan, SONG Jiancheng, et al. Bar-to-bar Discharge Patterns of Stator Windings for 10 kV Asynchronous Motors[J]. High VoltageApparatus, 2017, 53(1): 83-89.
KANG Ailiang, LIN Lingyan, SONG Jiancheng, et al. Bar-to-bar Discharge Patterns of Stator Windings for 10 kV Asynchronous Motors[J]. High VoltageApparatus, 2017, 53(1): 83-89. DOI: 10.13296/j.1001-1609.hva.2017.01.014.
bar-to-bar discharge will be generated because of transverse tear of end-winding
which can generally reduce the insulating properties. In order to solve this problem
a real bar-to-bar discharge model is designed by abrading the junction region between the low resistance layer and the high resistance layer of a real stator winding. The experiment is performed in the electromagnetic shielding room and the distribution patterns of bar-to-bar discharge under different voltages are analyzed. Hot pot distribution in the discharge region is observed and recorded through infrared camera. The research will provide a judging basis for the on-line monitoring and fault diagnosis of the 10 kV three phase asynchronous motors.