Research on Mechanical Fault Mechanism Analysis and Feature Extraction Technology Based on Low Voltage DC Circuit Breaker
Research & Analysis|更新时间:2025-04-26
|
Research on Mechanical Fault Mechanism Analysis and Feature Extraction Technology Based on Low Voltage DC Circuit Breaker
High Voltage ApparatusVol. 60, Issue 2, Pages: 26-37(2024)
作者机构:
1.西安交通大学电力设备电气绝缘国家重点实验室,西安 710049
2.华能河南中原燃气发电有限公司,河南 驻马店 463000
作者简介:
基金信息:
National Natural Science Foundation of China(U2166214);Key R&D Program of Shaanxi(2022GXLH-01-11);Natural Science Basic Research Program of Shaanxi(2023-JC-JQ-41);China Postdoctoral Science Foundation(2022M712510);State Key Laboratory of Electrical Insulation and Power Equipment(EIPE23111;EIPE23408;EIPE23314)
YE Yijun, GUO Jiajun, ZHANG Zijian, et al. Research on Mechanical Fault Mechanism Analysis and Feature Extraction Technology Based on Low Voltage DC Circuit Breaker[J]. High voltage apparatus, 2024, 60(2): 26-37.
DOI:
YE Yijun, GUO Jiajun, ZHANG Zijian, et al. Research on Mechanical Fault Mechanism Analysis and Feature Extraction Technology Based on Low Voltage DC Circuit Breaker[J]. High voltage apparatus, 2024, 60(2): 26-37. DOI: 10.13296/j.1001-1609.hva.2024.02.002.
Research on Mechanical Fault Mechanism Analysis and Feature Extraction Technology Based on Low Voltage DC Circuit Breaker
DC circuit breaker is the core protection equipment of DC traction power supply system of rail transit and the guarantee of safe operation of DC power supply system
it is therefore very important to ensure its stable operation. As for the mechanical structure characteristics of DC traction circuit breaker in this paper
the mechanical fault simulation experiment of circuit breaker is performed. The current and vibration signals of the opening and closing coils are selected as the monitoring physical quantities to study its mechanical fault mechanism and feature extraction method. The hardware device of signal acquisition is developed
and the experimental platform of mechanical fault simulation of DC circuit breaker is set up to simulate six kinds of common mechanical faults. The coil current and vibration signals under different faults are collected for feature extraction and fault mechanism analysis
which can provide theoretical support for mechanical fault diagnosis of low-voltage DC circuit breaker.
Review on Mechanical Fault Diagnosis Methods for High-voltage Circuit Breakers
Extraction Method of GIS Vibration Signal Characteristic Based on Composite Feature
Structural Parameter Optimization of Superconducting Current Limiter Based on MOPSO Algorithm
Mechanical Condition Identification of On-load Tap-changer Based on Optimized TQWT and Twin SVM
Study on Difference of Vibration Characteristics of GIS in Operation
Related Author
GUAN Yonggang
YANG Yuanwei
ZHONG Jianying
CHENG Tiehan
MA Xingguang
WANG Xiaoyi
HUANG Rui
JIANG Jianping
Related Institution
State Key Lab of Control and Simulation of Power Systems and Generation Equipments,Department of Electrical Engineering,Tsinghua University
Pinggao Co.,Ltd.
Shandong Provincial Key Laboratory of Ultra-high Voltage Power Transmission Technology and Equipment,School of Electrical Engineering,Shandong University
State Grid of China Technology College
State Grid Shandong Electric Power Maintenance Company