Finite Element Analysis on 3D Axial Magnetic Field and Eddy Current in Cup Shape Axial Magnetic Vacumm[J]. High voltageapparatus, 2000, (2): 18-21. DOI: 10.13296/j.1001-1609.hva.2000.02.005.
Finite Element Analysis on 3D Axial Magnetic Field and Eddy Current in Cup Shape Axial Magnetic Vacumm
the AMF of the VI is calculated by finite element method software
which include 3D DC AMF and 3D AC AMF in the gap. The induced eddy current in the contacts is also analyzed. The results show that AC AMF is different from that of the DC AMF because eddy current exists. The eddy current influences the AMF distribution in the center of contact most heavily