CHEN Chang-long, WANG Li-ming. Electric Field Calculation for Electric Locomotive Roof Insulator[J]. High voltageapparatus, 2011, 47(1): 53-57. DOI: 10.13296/j.1001-1609.hva.2011.01.003.
Electric Field Calculation for Electric Locomotive Roof Insulator
the reason that caused by ice accumulation covered a large proportion.How to effectively reduce the forming of ice on roof insulator used in electric locomotive and improve the flashover characteristic of icing insulator
has became a serious problem that urgently needs tobe addressed in electric railway in North China.In connection with actual situation of the ice coating flashover on roof insulator
we adopted the design of combination insulator that partial surface was covered with semi-conducting glaze.Electric field around the insulator surface with changing of the position and length of semi-conducting glaze was calculated by finite element method.In the end
the optimization coating design of the semi-conducting glaze was given and coated on the roof insulator surface.