LI Xin-feng, WEI Guang-hui, PAN Xiao-dong. Effect of Terminal Load on Terminal Response of Coaxial Line under Radiation of Continuous Wave[J]. High voltageapparatus, 2012, 48(8): 7-12.
LI Xin-feng, WEI Guang-hui, PAN Xiao-dong. Effect of Terminal Load on Terminal Response of Coaxial Line under Radiation of Continuous Wave[J]. High voltageapparatus, 2012, 48(8): 7-12. DOI: 10.13296/j.1001-1609.hva.2012.08.003.
Effect of Terminal Load on Terminal Response of Coaxial Line under Radiation of Continuous Wave
To investigate the coupling effect of coaxial line on terminal equipment under radiation of continuous wave
an experimental system of electromagnetic radiation to coaxial line are constructed
where the electromagnetic coupling voltage response at coaxial line terminal under different load is analyzed.The results show that: When the terminal load of shielding box is matched and the terminal load of shielding chamber is changed
the voltage response of terminal load of shielding chamber increases with the increase of terminal resistance.When the terminal load of shielding chamber is matched and the terminal load of shielding box is changed
the varying law of terminal voltage response and its amplitude of shielding chamber keep steady