OUYANG Le-cheng, WU Guang-ning, LI Tian-zhi, et al. Discussion on the Life Test Method of Motor Train Vacuum Circuit Breaker under Frequent Interruption[J]. High voltageapparatus, 2012, 48(9): 83-87+91.
OUYANG Le-cheng, WU Guang-ning, LI Tian-zhi, et al. Discussion on the Life Test Method of Motor Train Vacuum Circuit Breaker under Frequent Interruption[J]. High voltageapparatus, 2012, 48(9): 83-87+91. DOI: 10.13296/j.1001-1609.hva.2012.09.016.
Discussion on the Life Test Method of Motor Train Vacuum Circuit Breaker under Frequent Interruption
Motor train vacuum circuit breaker(VCB) is the key part of power supply control system
which is very important to safe and stable operation of motor train.The working conditions of motor train VCB are very peculiar
which makes its life-span characteristic very different from common VCB in power system.So the life test methods for common VCB are not suitable for motor train VCB.In order to test the lifetime of motor train VCB
a new life test method is put forward for the CRH2A type motor train VCB
including frequency withstand voltage test
impact withstand voltage test
mechanical endurance test
and contact resistance measurement of contact terminal in arc extinguishing chamber.Consequently
the relationships between the test data and the breaking number can be obtained to analyze the life limits of the motor train VCB.