CHENG De-sheng, LI Ge, XIE Fei, et al. Numerical Simulation of Heat Transfer Performance of Power Transmission Lines of Series Snubber of EAST-NBI[J]. High voltageapparatus, 2013, 49(11): 49-54.
CHENG De-sheng, LI Ge, XIE Fei, et al. Numerical Simulation of Heat Transfer Performance of Power Transmission Lines of Series Snubber of EAST-NBI[J]. High voltageapparatus, 2013, 49(11): 49-54. DOI: 10.13296/j.1001-1609.hva.2013.11.010.
Numerical Simulation of Heat Transfer Performance of Power Transmission Lines of Series Snubber of EAST-NBI
When transmission lines of ion source are inserted into the high voltage snubber
the temperature of the transmission lines rise due to accumulation of heat energy from electricity. Thermal balance temperature of the transmission lines is an important parameter for safe operation of ion source and selection of the insulation material for the transmission line. In this paper
the heat transfer performance of the transmission line inserted into the series high voltage snubber is simulated. Simulation results show that the balance temperature of the transmission line is much higher than the soft point temperature of the insulation material; and for a transmission line model of two meters in length between the snubbers
extending the length can decrease the temperature of the transmission line in the snubbers.