LIU Bingjie, TANG Yuan, CHEN Weigen. Analysis on Resonant Photoacoustic Cell in Photoacoustic Spectroscopy Monitoring System for Detecting Trace Gases in Transformer Oil[J]. High voltageapparatus, 2014, 50(2): 42-47.
LIU Bingjie, TANG Yuan, CHEN Weigen. Analysis on Resonant Photoacoustic Cell in Photoacoustic Spectroscopy Monitoring System for Detecting Trace Gases in Transformer Oil[J]. High voltageapparatus, 2014, 50(2): 42-47. DOI: 10.13296/j.1001-1609.hva.2014.02.002.
Analysis on Resonant Photoacoustic Cell in Photoacoustic Spectroscopy Monitoring System for Detecting Trace Gases in Transformer Oil
Photoacoustic spectroscopy(PAS) is a new method for trace gas detection
and it can be well applied to detection of dissolved gases in transformer oil.Photoacoustic cell(PA cell) is the core of the PAS monitoring system
which can reflect the system sensitivity effectively.In this study
the photoacoustic signal distribution of gas and the quantitative relationship between the resonator geometry and the characteristic parameters of PA cell performance were simulated.Two PA cells with different geometric parameters of resonance were designed to investingate the response characteristics of PA cell experimentally
and the results show that when the resonator is 120 mm in length and 3 mm in radius
the PA cell made of stainless steel exhibits better gas response performance.The stainless steel resonant PA cell was used in acetylene gas detection.The theoretical and experimental results obtained in this study may support further improvement of on-line PAS gas monitoring system and optimum design of PA cell with high sensitivity.