CHEN Xingang, MA Zhipeng, HUANG Huixian, et al. Design and Study of Signal Transmission Model of One-dimension Photoacoustic Cell for Detection of Dissolved Gases in Transformer Oil[J]. High voltageapparatus, 2014, 50(4): 35-41.
CHEN Xingang, MA Zhipeng, HUANG Huixian, et al. Design and Study of Signal Transmission Model of One-dimension Photoacoustic Cell for Detection of Dissolved Gases in Transformer Oil[J]. High voltageapparatus, 2014, 50(4): 35-41. DOI: 10.13296/j.1001-1609.hva.2014.04.007.
Design and Study of Signal Transmission Model of One-dimension Photoacoustic Cell for Detection of Dissolved Gases in Transformer Oil
According to the principle of photoacoustic(PA) gas detection and transmission line
this paper presented and improved model of one-dimension PA cell signal transmission line with analogy analysis. The model simulation presented the resonant frequency
quality factor and cell constant of PA cell. It also presented the relationship between these performance indexes of PA cell and its geometrical parameters. The model simulation results show that the correlation can be found between lengths of resonant cavity and resonant frequency
and the correlation between lengths and radius of resonant cavity also can be found. The model simulation has high theoretical instructive significance.