Ultrasonic Location of Partial Discharge in Transformer Based on Improved Three-platform Direction Finding Principle
An ultrasonic location method of partial discharge(PD)in transformer based on the improved threeplatform direction-finding principle is proposed. The method takes it into consideration that azimuth and elevation error will enlarge positioning error with the increase of the distance between PD source and platform. The distance between the auxiliary anchor point and the direction finding line is proportional to the average of the maximum peaks of received signals. The average of the maximum peaks of received signals from different sensors in same array is measured through laboratory simulation experiment
and the experiment needs to be conducted for several times if the distance between PD source and platform is different. When the average of the maximum peaks is obtained
the distance between PD source and platform can be easily achieved on the basis of the relationship curve. Considering that the position of auxiliary anchor point is on the common perpendicular and the distance between auxiliary anchor point and direction finding line is proportional to the average of the maximum peaks
a plane circle can be determined by three auxiliary anchor points following the three-platform direction-finding principle
and the center of the circle is taken as the position of PD source. Experiment verifies that the proposed method can improve the location success rate and accuracy of transformer PD position.
THE PROGRAM DEVELOPMENT OF PD LOCATION SYSTEM USED IN LARGE-SIZE TRANSFORMER
Research on Application of Microphone-optimized Spiral Arrays-based Acoustic Imaging Devices in Partial Discharge Localization
Study on Fiber Interferometric Partial Discharge Ultrasonic Sensing Method Based on Acoustic-optic Modulation and RF Phase Detection
High-frequency Sensing Technology of Partial Discharge of Switchgear Cabinet for Wind Solar & Energy Storage Stations in Gobi Deserts
Research on Influence of Piezoelectric Material Properties and Element Size on Sensitivity of Piezoelectric Sensor for Partial Discharge Monitoring of Transformer
Related Author
SONG Dong-sheng 1
WANG Qing 2
ZHANG Ke 2
YAN Li-wei 1
YUE Song
GAO Fei
HAN Shuai
DONG Haoyuan
Related Institution
Naval Logistics Institute
North China Electric Power University
海军后勤学院 天津300450
河北保定071003
Electric Power Research Institute of State Grid Tibet Company