SUN Jingjing, XU Nan, XIONG Haibo, et al. Comparison on Discharge Characteristics of Gas-liquid Two-phase Dielectric Barrier Discharge with Different Electrode Structures[J]. High voltageapparatus, 2017, 53(4): 79-85.
SUN Jingjing, XU Nan, XIONG Haibo, et al. Comparison on Discharge Characteristics of Gas-liquid Two-phase Dielectric Barrier Discharge with Different Electrode Structures[J]. High voltageapparatus, 2017, 53(4): 79-85. DOI: 10.13296/j.1001-1609.hva.2017.04.014.
Comparison on Discharge Characteristics of Gas-liquid Two-phase Dielectric Barrier Discharge with Different Electrode Structures
放电电流可达140 m A。电极布置差异导致电场不均匀系数的不同是放电特性出现差异的主要原因。随着电压幅值的增加
3种电极结构放电增强
放电功率和分子振动温度增加
电子密度也增加。
Abstract
The discharge characteristics of dielectric barrier discharge(DBD)in gas-liquid mixture with the edgeplate
tube-plate
and mesh wire-plate electrode structures at atmospheric pressure in air were studied and compared by measuring voltage and current waveforms
taking lighting emission images
and using spectrum analysis.The changing trends of electrical parameters with the applied voltage were studied. Moreover
the discharge characteristics of DBD in gas-liquid mixture with different electrode structures were analyzed by combining gas dis-charge theory. The results show that the voltage and current waveforms
Lissajous figures
and optical emission spectrum of three electrode structure DBDs in gas-liquid mixture show different characteristics. At the same experimental conditions
the mesh wire-plate electrode structure DBD in gas-liquid mixture has the strongest discharge and the largest dissipated discharge power
and the discharge current can reach 140 m A. The arrangement of the electrode leads to difference non-uniform coefficient on electric field distribution
which is the main reason for the difference on discharge characteristics. With the increase in voltage amplitude
the discharge become strong
and the discharge power
molecular vibrational temperature and electron excited density all increase.