浏览全部资源
扫码关注微信
1. State Grid Shijiazhuang Electric Power Supply Company
2. State Grid Hebei Electric Power Research Institute
3. State Key Laboratory of Electrical Insulation and Power Equipment,Xi'an Jiaotong University
Published:2017
移动端阅览
[1]WANG Qingliang,YANG Hua,ZHANG Qiaogen.Effects of Contaminations on Corona Pulse Inception Characteristics of HVDC Conductor[J].高压电器,2017,53(06):42-47.
WANG Qingliang, YANG Hua, ZHANG Qiaogen. Effects of Contaminations on Corona Pulse Inception Characteristics of HVDC Conductor[J]. High voltageapparatus, 2017, 53(6): 42-47.
[1]WANG Qingliang,YANG Hua,ZHANG Qiaogen.Effects of Contaminations on Corona Pulse Inception Characteristics of HVDC Conductor[J].高压电器,2017,53(06):42-47. DOI: 10.13296/j.1001-1609.hva.2017.06.008.
WANG Qingliang, YANG Hua, ZHANG Qiaogen. Effects of Contaminations on Corona Pulse Inception Characteristics of HVDC Conductor[J]. High voltageapparatus, 2017, 53(6): 42-47. DOI: 10.13296/j.1001-1609.hva.2017.06.008.
Contaminations adhering on HVDC transmission line will change its corona characteristics to generate electromagnetic pollution. The corona-induced radio interference and audible noise become important factors influencing the configuration and costs of transmission project. For understanding the effects of contaminations on the corona pulse characteristics of an HVDC transmission line
a corona cage was adopted to experimentally investigate corona pulse inception voltage and corona pulse characteristics of the conductors with different contaminations on surfaces. The contaminations include simulated contaminations
carbon powder
cement and fine sand. The results show that when conductor is covered with contaminations
the positive polarity corona pulses have high amplitude and low frequency
while the negative polarity corona pulses have low amplitude and incremental high frequency components. The corona pulse inception voltage presents a negatively exponential decrease with the increase of contamination density
showing a saturation trend. Fine sand shows the greatest effect on the corona pulse inception voltage with positive polarity
while cement shows the least effect. A function of corona inception voltage and surface contamination density is given. This study may provide reference for design of transmission lines.
Contaminations adhering on HVDC transmission line will change its corona characteristics to generate electromagnetic pollution.The corona-induced radio interference and audible noise become important factors influencing the configuration and costs of transmission project.For understanding the effects of contaminations on the corona pulse characteristics of an HVDC transmission line
a corona cage was adopted to experimentally investigate corona pulse inception voltage and corona pulse characteristics of the conductors with different contaminations on surfaces.The contaminations include simulated contaminations
carbon powder
cement and fine sand.The results show that when conductor is covered with contaminations
the positive polarity corona pulses have high amplitude and low frequency
while the negative polarity corona pulses have low amplitude and incremental high frequency components.The corona pulse inception voltage presents a negatively exponential decrease with the increase of contamination density
showing a saturation trend.Fine sand shows the greatest effect on the corona pulse inception voltage with positive polarity
while cement shows the least effect.A function of corona inception voltage and surface contamination density is given.This study may provide reference for design of transmission lines.