LIU Yunpeng, ZHONG Zheng, LI Lifen, et al. Influence of Salt Spray on the Breakdown Voltage of Rod-plate Short Air Gap Under Lighting Impulses[J]. High voltageapparatus, 2018, 54(9): 1-5+11.
LIU Yunpeng, ZHONG Zheng, LI Lifen, et al. Influence of Salt Spray on the Breakdown Voltage of Rod-plate Short Air Gap Under Lighting Impulses[J]. High voltageapparatus, 2018, 54(9): 1-5+11. DOI: 10.13296/j.1001-1609.hva.2018.09.001.
Influence of Salt Spray on the Breakdown Voltage of Rod-plate Short Air Gap Under Lighting Impulses
The influence of haze on the insulation of transmission line cannot be ignored. To reveal the influence ofsalt spray on breakdown voltage of air gap under lightning impulses
the rod-plane air gap model with the lowestbreakdown voltage was adopted to conduct the voltage breakdown test under different haze conductivity. The sizes ofthe short air gaps of the model are 5
10 and 15 cm
respectively. Results show that the breakdown voltage of theshort air gaps is affected by the haze conductivity and the size of the air gap
the breakdown voltage decreases withthe increase of haze conductivity
and the influence of the haze conductivity on the breakdown voltage gets weaker asthe gap size increases. The particle swarm optimization was used to fit the experimental data
hence the calculationformula of the breakdown voltage under lighting impulses was obtained. This study may provide a reference for the en-hancement of external insulation of transmission line in haze environment.