BAO Peng, SUN Xin. Analysis of Internal Leakage Fault of HMB4/8 Hydraulic Spring Operating Device[J]. High voltageapparatus, 2019, 55(2): 220-226. DOI: 10.13296/j.1001-1609.hva.2019.02.032.
Analysis of Internal Leakage Fault of HMB4/8 Hydraulic Spring Operating Device
The structure and working principle of HMB4/8 spring stored energy hydraulic operating device are expounded.The oil circuit system and sealing structure of HMB4/8 hydraulic operating device are analyzed and studied.The phenomena of different internal leakage faults are analyzed in depth
and the judgment methods and countermeasures of fault points are put forward.The correctness and validity of the method for judging the internal leakage of HMB8.3 operating device are verified by an inspection and treatment of the internal leakage fault of the mechanism.