Design of SF6 Gas Bushing External Insulation Structure on High Voltage Converter Transformer Valve Side
The converter transformer valve side bushing is an important equipment to realize the electrical connection between the converter transformer and the valve tower. The paper mainly discusses the design of the external insulation structure. The research content is divided into three parts
the actual operating environment and the characteristics of the voltage and current waveforms of converter transformer bushing are discussed. The design and analysis of the hollow composite insulator
corona ring and tail end of the bushing has been done. The three dimensional electric field simulation model has been set up to calcu
late and analyze the external insulation performance of the bushing.The results show that the main insulation of the bushing is fit to the capacitive structure
and the end of the bushing should be equipped with apple type corona ring. The insulation distance of the hollow composite insulator is designed as 7 490 mm. The insulation distance of the bushing tail is designed as 3110 mm. In the actual operating environment
the maximum field strength of the corona ring appears on the lower end surface
and the value is 2 386 V·mm
-1
. The results of the paper can provide the theoretical basis for the design of the external insulation of the converter transformer bushing used in the HVDC transmission project.
Analysis of Insulation Structure Design for High Altitude UHV Reactor Bushing
Development of 1 100 kV GIS Composite Bushing at Altitude of 4 000 m
Research on Influence of Piezoelectric Material Properties and Element Size on Sensitivity of Piezoelectric Sensor for Partial Discharge Monitoring of Transformer
Typical Fault Analysis Caused by Shielded Separable Connector
Simulation Study on the Influence of Electric Field of 500 kV Single Circuit Transmission Line on UAV
Related Author
ZHANG Shiling
PENG Zongren
SUI Xiangxu
LU Peng
LIU Xu
WANG Lijuan
FANG Qi
WANG Lei
Related Institution
Henan Pinggao Electric Co, Ltd
Department of Electric Power Sensing Technology, Global Energy Interconnection Research Institute Co., Ltd.
Wuzhong Company of State Grid Ningxia Power Co
State Grid Ningxia Electric Power Corporation Research Institute
China Southern Power Grid General Aviation Co., Ltd.