LI Guangyao, YIN Xianbin, WU Guangning. Study on the Creepage Discharge of Roof Insulators Due to Artificial Erosion[J]. High voltageapparatus, 2019, 55(9): 143-149.
LI Guangyao, YIN Xianbin, WU Guangning. Study on the Creepage Discharge of Roof Insulators Due to Artificial Erosion[J]. High voltageapparatus, 2019, 55(9): 143-149. DOI: 10.13296/j.1001-1609.hva.2019.09.019.
Study on the Creepage Discharge of Roof Insulators Due to Artificial Erosion
To investigate the changes in the creepage discharge of high-speed train roof insulators in dust environment
erosion test of the roof insulator was carried out to observe the changes in its surface roughness
hydrophobicity and flashover voltage.Results show that:1)the surface hydrophobicity of the insulator samples with different erosion time is similar
and the sandpaper mesh is the main factor influencing hydrophobicity change;2)with the mesh of sandpaper increasing
the longitudinal insulation dry flashover voltage decreases first and then increases
and the transverse dry flashover voltage increases after the first drop then rises again the variation regularity of the transverse wet flashover voltage is consistent with the longitudinal wet flashover voltage
presenting U-shape.Analysis indicates that the increases of creepage distance and electric field distortion both affect the flashover voltage.In addition
the mechanism of dust erosion affecting the creepage discharge of roof insulators was also revealed.