XIANG Enxin, ZHOU Wanya, WANG Ke, et al. Discharge in High Voltage Cable Joint with Defect on Outer Semi-conductive Layer[J]. High voltageapparatus, 2020, 56(3): 135-140.
XIANG Enxin, ZHOU Wanya, WANG Ke, et al. Discharge in High Voltage Cable Joint with Defect on Outer Semi-conductive Layer[J]. High voltageapparatus, 2020, 56(3): 135-140. DOI: 10.13296/j.1001-1609.hva.2020.03.020.
Discharge in High Voltage Cable Joint with Defect on Outer Semi-conductive Layer
high frequency current transformer(HFCT) and hard ware real time data acquisition technologies
partial discharge induced by perforative defect in outer semi-conductive layer of prefabricated cable joint was detected
and the discharge mechanism was investigated in the respect of electric field distribution and the discharge model to acknowledge the discharge characteristics of cable joint with scratch on the outer semi-conductive layer.The results show that the sensitivity and signal to noise ratio of the high frequency current coupling method is lower than that of the pulse current method
thus HFCT would miss the discharge signal induced by the perforative defect.The switching and fault overvoltage may induce discharge in the defect of cable joint with scratch on the outer semi-conductive layer and the discharge will rapidly expand to the reinforced insulation and finally lead to the occurrence of a perforative discharge channel in reinforced insulation.Therefore
this kind of defect should be c arefully prevented in the period of manufacture and installation to ensure safe operation of cable joint.
Research on Application of Microphone-optimized Spiral Arrays-based Acoustic Imaging Devices in Partial Discharge Localization
Study on Fiber Interferometric Partial Discharge Ultrasonic Sensing Method Based on Acoustic-optic Modulation and RF Phase Detection
High-frequency Sensing Technology of Partial Discharge of Switchgear Cabinet for Wind Solar & Energy Storage Stations in Gobi Deserts
Research on Influence of Piezoelectric Material Properties and Element Size on Sensitivity of Piezoelectric Sensor for Partial Discharge Monitoring of Transformer
Influence of Environmental Factors on Insulation Performance of Separable Connector for 12 kV Gas Filling Switchgear Cabinet
Related Author
YUE Song
GAO Fei
HAN Shuai
DONG Haoyuan
LI Jun
LI Xin
LIU Chao
QIAO Hui
Related Institution
Electric Power Research Institute of State Grid Tibet Company
China Electric Power Research Institute Co., Ltd.
Iflytek Co., Ltd.
Electric Power Research Institute, State Grid Hebei Electric Power Co., Ltd.
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University