XU Jun, GAO Qi, ZHOU Fei, et al. Study on the Electric Field Distribution of 35 k V Bus with Wrapped Insulation Sheath Under Typical Fault Conditions[J]. High voltageapparatus, 2020, 56(6): 317-323.
XU Jun, GAO Qi, ZHOU Fei, et al. Study on the Electric Field Distribution of 35 k V Bus with Wrapped Insulation Sheath Under Typical Fault Conditions[J]. High voltageapparatus, 2020, 56(6): 317-323. DOI: 10.13296/j.1001-1609.hva.2020.06.046.
Study on the Electric Field Distribution of 35 k V Bus with Wrapped Insulation Sheath Under Typical Fault Conditions
The insulating sheath is wrapped in the busbar of the substation to play the role of anti-corrosion and insu-lation protection. However
when a foreign object is lapped on the busbar of the insulated sheath
the phase-to-phaseshort-circuit accident often occurs. The specific cause of the accident is not clear
which seriously affects the grid
safe and reliable operation. Based on the finite element method
the busbar model of the wrapped insulation sheathunder typical fault conditions(air gap defects and lapped foreign objects)is constructed. The three-dimensional pow-er frequency electric field calculation is carried out on the wrapped insulation sheath busbar
and the insulation pro-tection is analyzed. The internal and surface electric field distribution of the insulating sheath caused by the internalair gap defect and the external foreign matter overlap
and the influence of the thickness of the insulating sheath onthe electric field distribution is studied. The results show that when there is air gap defect inside the busbar wrappedwith insulating sheath and external foreign matter overlap
electric field distortion will occur in the inner and surfaceof the insulating sheath. The degree of electric field distortion is: lapped metal>lapped wet branch>lapped drybranches>heat shrinkable air gap;increasing the thickness of the insulating sheath will help to improve the electricfield distortion on the surface and the inner part of the insulating sheath caused by foreign matters
which is differentto the metal The distortion of electric field can be reduced by 68%.
Study on Seismic Performance Improvement Methods for Gas-insulated Transmission Lines (GIL) in Ultra-high Voltage Converter Station
Research on Influence of Piezoelectric Material Properties and Element Size on Sensitivity of Piezoelectric Sensor for Partial Discharge Monitoring of Transformer
Study on Temperature Distribution of Epoxy Insulated Power Electronic Transformer Based on Fluid-solid-structure Coupling
Analysis of Maximum Compression Displacement and Fatigue Life of Bellows
Related Author
YANG Rui
SI Xiaochuang
FANG Qi
XU Zhongxun
FEI Xiang
JIANG Chengbo
ZHANG Xinmiao
YUAN Duanpeng
Related Institution
Henan Pinggao Electric Co., Ltd.
Pinggao Group Co., Ltd.
CSG Extra High Voltage Power Transmission Company, Dali Bureau
China Southern Power Grid Co., Ltd.
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University