RUAN Mianhui, CHEN Jianfu, LIU Bo, et al. Design of a 10kV Mechanical HVDC Circuit Breaker[J]. High voltageapparatus, 2020, 56(9): 260-266. DOI: 10.13296/j.1001-1609.hva.2020.09.038.
In order to meet the requirement of the demonstration project of the state key special project of the AC/DC hybrid distributed renewable energy technology in dongguan park
this paper presents a development scheme of10 kV mechanical DC circuit breaker
describes its topological structure and parameters design of key components
and then builds a simulation model based on PSCAD/EMTDC software to simulate the current interruption process
and corrects the parameters.Finally
a LC low-frequency oscillation test circuit is constructed.The positive and reverse high-current breaking tests of the developed 10 kV mechanical HVDC circuit breaker prototype are carried out.The developed prototype successfully interrupts 10 kA positive current and reverse current
the breaking time is 8.2~8.3 ms
full current breaking time is 12.2~12.3 ms
and the peak transient interruption voltage is 16.0 kV.