Lightning Overvoltage Protection of Wind Turbine Blade Laid De-icing Carbon Fiber Net
In order to solve the problem of icing on the surface of wind turbine blade
carbon fiber net laid in the wind turbine blade
heating and melting ice.When lightning strikes flash-grounding device on wind turbine blade
the blade cavity between the lead-down line and the carbon fiber net occurs breakdown.In order to study the breakdown mechanism of wind turbine blades with de-icing carbon fiber net during lightning strike
in this paper
model and the model of 690 V power supply circuit are established by using ATP-EMTP.The lightning current amplitude
front time
SPD installation position and number
and grounding resistance of wind turbine are analyzed to calculate the transient overvoltage between lead-down line and carbon network when lightning strikes the blade.The lightning protection mode of equipotential connection is proposed.The results show that
when the lightning strikes occur
the voltage difference between lead-down line and carbon fiber net far exceeds the insulation strength of air gap inside the blade and the insulation strength of the cable surface material.Overvoltage difference is positively correlated with lightning current amplitude.When the lightning current amplitude is unchanged
the overvoltage difference decreases rapidly with the increase of front time.The overvoltage difference decreases significantly with the increase of SPD installation group
the optimal installation mode of SPD is obtained by simulation.When SPD is not installed
the transient overvoltage decreases slightly with the increase of grounding resistance;when SPD is installed with the optimal installation mode
even if the grounding resistance of the wind turbine changes
the difference of induced voltage between the lead-down line and the carbon fiber net is almost unchanged.