WANG Jilai, WANG Pengcheng, ZHANG Weizhen, et al. Study on Lightning Transient Characteristic of Tunnel Traction Sectioning Post and Electromagnetic Compatibility of Its Secondary Equipment[J]. High voltage apparatus, 2024, 60(1): 108-117.
DOI:
WANG Jilai, WANG Pengcheng, ZHANG Weizhen, et al. Study on Lightning Transient Characteristic of Tunnel Traction Sectioning Post and Electromagnetic Compatibility of Its Secondary Equipment[J]. High voltage apparatus, 2024, 60(1): 108-117. DOI: 10.13296/j.1001-1609.hva.2024.01.013.
Study on Lightning Transient Characteristic of Tunnel Traction Sectioning Post and Electromagnetic Compatibility of Its Secondary Equipment
generate overvoltage and overcurrent in the sectioning post
produce transient electromagnetic interference to the secondary equipment in the switch cabinet of sectioning post and affect normal operation of the equipment. As for a tunnel sectioning post of electrification railway in this paper
the transient simulation under lightning strike is set up
the overvoltage and overcurrent are calculated when the contact line is struck by lightning in different position
and the transient electric and magnetic field distribution in the 27.5 kV switch cabinet is calculated by using electromagnetic FEA model. The results show that
overvoltage and overcurrent with large amplitude and high frequency will be generated in the sectioning post when lightning strikes contact line
the transient electric field of low voltage compartment of switchgear cabinet can reach 147.2 V/s
the transient magnetic field can reach 15.85 kA/m
which exceeding the amplitude specified by the standard. It is therefore necessary to consider the corresponding electromagnetic shielding measures for the secondary equipment. The results in this paper have certain reference for protection of overvoltage and overcurrent due to lightning strikes of traction network and electromagnetic compatibility design of secondary equipment in the switch cabinet.