Study and Design of Rogowski Coil for Partial Discharge Signal Measurement
Research & Analysis|更新时间:2025-04-26
|
Study and Design of Rogowski Coil for Partial Discharge Signal Measurement
High Voltage ApparatusVol. 61, Issue 1, Pages: 63-71(2025)
作者机构:
1.三峡大学湖北省输电线路工程技术研究中心,湖北 宜昌 443002
2.三峡大学电气与新能源学院,湖北 宜昌 443002
3.浙江赛禄克电气有限公司,浙江 温州 325602
作者简介:
基金信息:
National Natural Science Youth Foundation of China(51707105);Open Foundation of State Key Laboratory of Intense Pulsed Radiation Simulation and Effect(SKLIPR2008)
JIANG Jinbo, CHEN Guifeng, LUO Zheng, et al. Study and Design of Rogowski Coil for Partial Discharge Signal Measurement[J]. High voltage apparatus, 2025, 61(1): 63-71.
DOI:
JIANG Jinbo, CHEN Guifeng, LUO Zheng, et al. Study and Design of Rogowski Coil for Partial Discharge Signal Measurement[J]. High voltage apparatus, 2025, 61(1): 63-71. DOI: 10.13296/j.1001-1609.hva.2025.01.007.
Study and Design of Rogowski Coil for Partial Discharge Signal Measurement
As for the on-line measurement and monitoring requirement of partial discharge signals
a kind of broad-band (100 kHz-50 MHz) and high sensitivity (5.64 V/A) Rogowski coil with nickel zinc ferrite core is studied and designed in this paper. Firstly
the operating modes and frequency characteristics of the Rogowski coil are analyzed
and the conditions of the coil working in different operating modes as well as the influencing factors of the frequency band and its sensitivity of the coil under self-integration operating mode are derived. Then
Pspice is used to set up the equivalent circuit model for coil parameters scanning and verification of the derived theory. The integral conditions are simplified by changing the geometric parameters of the coil to determine the magnetic core size
coil turns and the optimal value of terminal resistance. Finally
five coils with the same parameters are fabricated and the square-wave response of the coils is analyzed by signal generator to verify their operating modes and
at the same time
the frequency band and sensitivity of the coils are also calibrated. The experimental results show that the designed Rogowski coil has good performance and can meet the measurement requirements of high frequency partial discharge signal.
Research on Influence of Piezoelectric Material Properties and Element Size on Sensitivity of Piezoelectric Sensor for Partial Discharge Monitoring of Transformer
Calibration of UHF Sensor for Detection of Partial Discharge in Transformer
Investigation of Improvement of Sensitivity Verification of Partial Discharge Detection Using UHF Method in GIS
Study on the Detection Sensitivity of High-frequency Current Method to Capacitor Partial Discharge
Research on Application of Microphone-optimized Spiral Arrays-based Acoustic Imaging Devices in Partial Discharge Localization
Related Author
WANG Yan
CHEN Chuan
LIU Yongbin
GAO Jinghui
ZHU Jiayi
LI Hui
CHEN Jiangbo
ZHANG Xi
Related Institution
Department of Electric Power Sensing Technology, Global Energy Interconnection Research Institute Co., Ltd.
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University
High Voltage Department,China Electric Power Research Institute
Sichuan Electric Power Research Institute
State Key Laboratory of Control and Simulation of Power System and Generation Equipment,Department of Electrical Engineering,Tsinghua University