浏览全部资源
扫码关注微信
中国电力科学研究院有限公司,武汉 430074
桂林电力电容器有限责任公司,广西桂林 541004
国家电网有限公司,北京 100031
Received:25 June 2025,
Revised:2025-09-18,
Published:16 January 2026
移动端阅览
WANG Ling, FENG Yu, GU Fengbiao, et al. Error Performance Optimization Design of a Novel CVT with Added Capacitor
WANG Ling, FENG Yu, GU Fengbiao, et al. Error Performance Optimization Design of a Novel CVT with Added Capacitor
在常规电容式电压互感器(CVT)的分压器低压端串接电容
C
3
实现谐波数据准确测量已被证实是一种可行技术,探求其误差特性并提出优化控制措施,对其工程应用具有重要意义。文中针对此类新型CVT,开展了其结构和误差特性分析。首先明确了二次绕组与谐波测量部分间的相互影响,由此获知分压器电容量偏差和谐波测量端负荷为影响其谐波测量端误差特性的关键参量,在此基础之上提出了谐波测量端的误差控制方法,最后通过试验验证了新型CVT的性能满足电网谐波监测要求、所提误差改进措施有效。在衡水110 kV怀甫站进行的挂网运行情况表明,该新型CVT运行平稳、获取的谐波监测数据准确有效。文中的研究结果为今后开展该类CVT的设计和使用奠定了技术基础。
The series connection of capacitor
C
3
at the low voltage side of the voltage divider of conventional capacitive voltage transformer (CVT) is proved to be a feasible method for accurate measurement of harmonic data. It is of great significance to explore its error characteristics and propose optimization control measures for its engineering application. In this paper
the structure and error characteristic analysis for the novel CVT are performed. First
the mutual influence between the secondary winding and the harmonic measurement is defined. From this it is know that the capacitance deviation of voltage divider and the load of harmonic measuring are the key parameters affecting the error characteristics of harmonic measuring terminal. On this basis
the error control method of the harmonic control terminal is propoed. Finally
it is proved through the test that the performance of the novel CVT can meet the requirements of harmonic monitoring of power grid and the proposed error modification measures are effective. It is shown by the operation of the novel CVT in 110 kV Huaifu substation of Hengshui that the operation of the novel CVT is stable and the obtained harmonic monitoring data is accurate and effective. The research results in this paper has laid the technical foundation for the development of the design and application of such type of CVT in the future.
张智,徐永海,张世聪,等.直流配电网电能质量指标研究综述[J].电力系统保护与控制,2025,53(3):172-187.
ZHANG Zhi,XU Yonghai,ZHANG Shicong,et al.Review of power quality indices of a DC distribution network[J]. Power System Protection and Control,2025,53(3):172-187.
刘颖英,冯丹丹,林才华,等.电能质量综合评估研究现状及发展趋势[J].电力系统保护与控制,2020,48(4):167-176.
LIU Yingying,FENG Dandan,LIN Caihua,et al. Current status and development trend of power quality comprehensive assessment[J]. Power System Protection and Control,2020,48(4):167-176.
陈砚圃,杨蕾,张介秋.基于组合余弦窗加权的高精度电力谐波分析[J].高压电器,2021,57(8):127-135.
CHEN Yanpu,YANG Lei,ZHANG Jieqiu. Analysis on high precision power harmonic based on combinatorial cosine window weighting method[J]. High Voltage Apparatus,2021,57(8):127-135.
王昭卿,常延朝,陈建磊,等.基于多融合MVMD-ISVM的复杂电能质量扰动识别方法[J].供用电,2024,41(9):70-77.
WANG Zhaoqing,CHANG Yanzhao,CHEN Jianlei,et al. Identification method for complex power quality disturbances based on multi-fusionMVMD-ISVM[J]. Distribution & Utilization, 2024,41(9):70-77.
李海涛,崔树春,尹华,等.基于随机森林算法的综合能源配电网电能质量评估方法与网架优化模型[J]. 电测与仪表,2024, 61(5):17-23.
LI Haitao,CUI Shuchun,YIN Hua,et al. Power quality evaluation method and grid optimization model of integrated energy distribution network based on stochastic forest algorithm[J]. Electrical Measurement & Instrumentation,2024,61(5):17-23.
任冲,任景,程林,等.基于构网型储能的直流近区新能源暂态过电压抑制方法[J].智慧电力,2025,53(9):1-9.
REN Chong,REN Jing,CHENG Lin,et al.Transient overvoltage suppression method for renewable energy sources near DC transmission systems based on grid-forming energy storage[J]. Smart Power,2025,53(9):1-9.
孙海斌,傅国斌,宋锐,等.面向新型电力系统的静态电压稳定评估方法研究[J].电力电容器与无功补偿,2025,46(2):9-14.
SUN Haibin,FU Guobin,SONG Rui,et al. Research on static voltage stability evaluation method for new power systems[J]. Power Capacitor & Reactive Power Compensation,2025,46(2):9-14.
凌子恕. 高压互感器技术手册[M]. 北京:中国电力出版社, 2005.
LING Zishu. Technical manual of high voltage instrument tranformer[M]. Beijing:China Electric Power Press,2005.
王欢,王忠东,卢树峰,等.基于误差状态模糊分析的电容式电压互感器内绝缘状态评价方法[J]. 电测与仪表,2024,61(4):73-80.
WANG Huan,WANG Zhongdong,LU Shufeng,et al. Internal insulation condition evaluation method for capacitor voltage transformerbased on fuzzy analysis of error condition[J]. Electrical Measurement&Instrumentation,2024,61(4):73-80.
陈东明,王建伟,李旸,等.电容式电压互感器典型故障及缺陷分析[J]. 电力电容器与无功补偿,2024,45(6):36-43.
CHEN Dongming,WANG Jianwei,LI Yang,et al. Analysis of typical faults and defects of capacitive voltage transformer[J]. Power Capacitor & Reactive Power Compensation,2024,45(6):36-43.
周文,梁纪峰,焦亚东,等.电容式电压互感器电压暂降测量误差分析及校正[J].中国电力,2022,55(7):49-58.
ZHOU Wen,LIANG Jifeng,JIAO Yadong,et al. Error analysis and correction of voltage sag measurement for capacitor voltage transformer[J]. Electric Power,2022,55(7):49-58.
黄之笛,武霁阳,彭光强,等.基于多次谐波注入的CVT宽频传输特性测试研究[J].电力电容器与无功补偿,2025,46(3):69-76.
HUANG Zhidi,WU Jiyang,PENG Guangqiang,et al. Research on wideband harmonic transmission characteristics test of CVT based on multi-harmonic injection[J]. Power Capacitor & Reactive Power Compensation,2025,46(3):69-76.
吴奇松,夏君宇,赵国庆,等. CVT电容分压器末端放电故障分析[J].变压器,2024,61(1):62-65.
WU Qisong,XIA Junyu,ZHAO Guoqing,et al. Analysis of discharge fault at end screen of CVT capacitor voltage divider[J]. Transformer,2024,61(1):62-65.
周存和.关于电容式电压互感器测量谐波电压的问题[J].电力电容器,2006,27(2):43-45.
ZHOU Cunhe. Some problem about the harmonic voltage measurement by capacitor voltage transformer[J]. Power Capacitor, 2006,27(2):43-45.
刘坤雄,陈一悰,张小庆,等.基于测量链的CVT谐波测量系统不确定度评价方法[J].智慧电力,2022,50(12):107-113.
LIU Kunxiong, CHEN Yicong, ZHANG Xiaoqing, et al. Uncertainty evalution method of CVT harmonic measurement system based on measurement chain[J]. Smart Power,2022,50 (12):107-113.
郭成,朱明星,段锐敏,等. CVT谐波测量修正方法研究[J].电力电容器与无功补偿,2022,43(2):57-63.
GUO Cheng,ZHU Mingxing,DUAN Ruimin,et al. Research on harmonic measurement and correction method ofCVT[J]. Power Capacitor & Reactive Power Compensation,2022,43(2):57-63.
代双寅,刘书铭,赵麒哲,等.基于CVT电容电流的谐波电压测量方法[J].电力系统保护与控制,2020,48(20):141-147.
DAI Shuangyin,LIU Shuming,ZHAO Qizhe,et al. A harmonic voltage measurement method based on CVT capacitor current[J]. Power System Protection and Control,2020,48(20):141-147.
陈东明,王建伟,李旸,等.电容式电压互感器典型故障及缺陷分析[J].电力电容器与无功补偿,2024,45(6):36-43.
CHEN Dongming,WANG Jianwei,LI Yang,et al. Analysis of typical faults and defects of capacitive voltage transformer[J]. Power Capacitor & Reactive Power Compensation,2024,45(6):36-43.
姚锡钦.一起110 kV电容式电压互感器二次电压异常的故障分析[J].变压器,2024,61(6):67-70.
YAO Xiqin.Fault analysis of secondary voltage anomaly of 110 kV capacitive voltage transformer[J]. Transformer,2024,61(6):67-70.
赵彦林,周志新,何亮,等.一起电容式电压互感器二次电压异常故障分析[J].电力电容器与无功补偿,2025,46(1):114-120.
ZHAO Yanlin,ZHOU Zhixin,HE Liang,et al. Analysis of an abnormal secondary voltage of capacitive voltage transformer[J]. Power Capacitor & Reactive Power Compensation,2025,46(1):114-120.
宋守龙,廖斌,顾风彪.电容式电压互感器铁磁谐振试验测控装置[J].电力电容器与无功补偿,2024,45(5):54-60.
SONG Shoulong,LIAO Bin,GU Fengbiao. Measurement and control device for ferro - resonance test of capacitor voltage transformer[J]. Power Capacitor & Reactive Power Compensation, 2024,45(5):54-60.
胡广富.基于电容式电压互感器的谐波电压测量研究[D].重庆:重庆大学,2022.
HU Guangfu. Research on harmonic voltage measurement based on capacitor voltage transformer[D]. Chongqing:Chongqing University,2022.
Instrument transformers-the use of instrument transformers for power quality:IEC TR 61869-103:2012[S].2012.
陈一悰,刘坤雄,冯雅琳,等.电容式电压互感器谐波监测技术综述[J].电力电容器与无功补偿,2022,43(5):70-75.
CHEN Yicong,LIU Kunxiong,FENG Yalin,et al. Review on harmonic monitoring technology of capacitor voltage transformer[J]. Power Capacitor & Reactive Power Compensation ,2022,43(5):70-75.
王玲,冯宇,杨柳,等.电容式电压互感器谐波测量方法研究[J].电力电容器与无功补偿,2021,42(1):95-100.
WANG Ling,FENG Yu,YANG Liu,et al. Study on harmonic measurement method of capacitor voltage transformer[J]. Power Capacitor & Reactive Power Compensation,2021,42(1):95-100.
肖耀荣,高祖绵.互感器原理与设计基础[M].沈阳:辽宁科学技术出版社,2003.
XIAO Yaorong,GAO Zumian. Principle and design basis of instrument tranformer[M]. Shenyang: Liaoning Science and Technology Press,2003.
互感器技术规范第6部分:具备谐波测量功能的电容式电压互感器:Q/GDW 12133.6—2021[S].2022.
Technical specification for instrument transformers - Part 6:Capacitor voltage transformers with harmonic measurement function:Q/GDW 12133.6—2021[S].2022.
电能质量监测设备通用要求:GB/T 19862—2016[S].2017.
General requirements for power quality monitoring equipment:GB/T 19862—2016[S].2017.
电能质量公用电网谐波:GB/T 14549—1993[S].1994.
Quality of electric energy supply harmonics in public supply network:GB/T 14549—1993[S].1994.
电磁兼容试验和测量技术供电系统及所连设备谐波、谐间波的测量和测量仪器导则:GB/T 17626.7—2017[S].2017.
Electromagnetic compatibility-testing and measurement techniquesgeneral guide on harmonics and interharmonics measurements and instrumentation,for power supply systems and equipment connected thereto:GB/T 17626.7—2017[S].2017.
谢伟伦,黄志威,刘小沛.杂散电容对CVT谐波测量影响的处理方法研究[J].电力电容器与无功补偿,2020,41(2):59-63.
XIE Weilun,HUANG Zhiwei,LIU Xiaopei. Study on the processing method of influence of stray capacitance on CVT harmonic measurement[J]. Power Capacitor & Reactive Power Compensation,2020,41(2):59-63.
刘俭,姜春阳,殷小东,等.谐波电压互感器宽频特性试验研究[J].中国测试,2021,47(8):130-136.
LIU Jian,JIANG Chunyang,YIN Xiaodong,et al. Study on frequency characteristics of harmonic voltage transformer[J]. China Measurement & Testing Technology,2021,47(8):130-136.
0
Views
19
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
陕公网安备 61010402000197